Basic parameters, working principle and purpose:
The DBH-25-35 pull-out free tripping single-phase circuit breaker works on the principle of combining bimetallic electric heating and electromagnetic tripping, and has a temperature compensation structure that can be used in a wide humidity range. The circuit breaker is used for overload or short circuit protection in aircraft AC/DC distribution systems.
Environmental adaptability:
Surrounding medium temperature: (-55~85) ℃
Sinusoidal vibration: frequency range (10-500) Hz, acceleration 10g
Acceleration: 10g
Impact: 50g
Electrical performance:
Extreme action current
At 25 ℃, the maximum holding current of the product is 115% of the rated current; The minimum tripping current is 150% of the rated current
At 85 ℃, the maximum holding current of the product is 85% of the rated current; The minimum tripping current is 150% of the rated current
-At 55 ℃, the maximum holding current of the product is 115% of the rated current; The minimum tripping current is 165% of the rated current
life
5000 working cycles of resistive load;
Inductive load 2500 working cycles, COS φ=0.6~0.7
Breaking capacity: DC 6000 A; Exchange 2000 A
Exterior installation: