AC115V Distribution Onboard SSPC-AC Solid State Distribution

The AC115V series solid power controller is a module that distributes DC power and provides protection functions. This controller can receive diverse input control signals, including switch inputs, data buses, etc. The solid-state power controller (SSPC) within the module can be controlled to turn on or off through the data bus. The working status of the module can be reported in real-time through the data bus. It can be widely used for power system distribution and management in fields such as aircraft, tanks, ships, and measurement and control. Product features: · Control input and output electrical isolation (≥ 2500Va. c.) · Output load up to 100A

The AC115V series solid power controller is a module that distributes DC power and provides protection functions. This controller can receive diverse input control signals, including switch inputs, data buses, etc. The solid-state power controller (SSPC) within the module can be controlled to turn on or off through the data bus. The working status of the module can be reported in real-time through the data bus. It can be widely used for power system distribution and management in fields such as aircraft, tanks, ships, and measurement and control.

Product Features:

·Control input and output electrical isolation (≥ 2500Va. c.)

·Output load up to 100A

·Adopting the VIAT48 standard module structure

·I2t load overcurrent protection and short-circuit tripping protection

·Provide multiple data buses (1553B, ARINC429,RS485,RS422,CAN)



Environmental parameters

project

minimum value

Maximum value

Company

working temperature

-40

105

Storage temperature

-55

one hundred and twenty-five

Shock (specified pulse)

100,11

(m/s2),ms


图片关键词


Load voltage detection, load current detection, protection method based on I2t curve, active current limiting, power filtering, load safety protection.

Input voltage range: 0-200V,

Rated input voltage 120Vd. c,

Output current: 5A (12H),

Insulation resistance: ≥ 100M Ω,

Dielectric withstand voltage: ≥ 500Vr. m.s,

Output leakage current: ≤ 10 μ A,

Control mode: Bus (RS422, RS485, CAN), optional switch control.