Intelligent power distribution system for transport aircraft AC primary power distribution solid-state power supply

The communication initial power distribution unit is used for the initial power distribution of the model AC distribution system. It completes the intelligent distribution and management of power by receiving bus control instructions or switch quantity instructions from the upper computer. It has functions such as switch status feedback, current, voltage, and frequency parameter feedback, overcurrent and short-circuit protection, overvoltage protection, undervoltage protection, leakage protection, and phase loss protection. At the same time, it has high reliability and safety indicators, good electromagnetic compatibility and environmental adaptability, small size, light weight, low power consumption, and easy maintenance. Main performance indicators: Operating voltage: 115Va. c./220Va. c./380Va. c

The communication initial power distribution unit is used for the initial power distribution of the model AC distribution system. It completes the intelligent distribution and management of power by receiving bus control instructions or switch quantity instructions from the upper computer. It has functions such as switch status feedback, current, voltage, and frequency parameter feedback, overcurrent and short-circuit protection, overvoltage protection, undervoltage protection, leakage protection, and phase loss protection. At the same time, it has high reliability and safety indicators, good electromagnetic compatibility and environmental adaptability, small size, light weight, low power consumption, and easy maintenance.

Main performance indicators:

Working voltage: 115Va. c./220Va. c./380Va. c. Working temperature: -40~85 ℃

Load power characteristics: ≤ 800A/Ch, 115/220/380Va. c. Load power frequency: 50Hz/400Hz

Control mode: switch control/bus control

Control mode: Three modes (remote control, local control, and emergency control)

Environmental adaptability: meets the relevant requirements of GJB1032-1990, GJB150A-2009, and GJB4-1983

Electromagnetic compatibility: meets the relevant electromagnetic environment requirements of GJB151A-1997

Communication interfaces: RS485, RS422, CAN, Ethernet, MIL-STD-1553B and other bus interfaces Electrical interfaces: connectors, busbars or terminals

Structural form: Standard chassis or customized chassis Average time between failures: up to 20000 hours