电流传感器是一种电气装置,平衡式霍尔电流传感器用于测量沿着特定电线的电流.它通过测量电流路径上电阻的电压降来实现这一点。这允许电流传感器生成流过线路的电流水平的估计值。电流传感器的输出可以是电压读数,也可以是持续电流,其大致与沿测试路径移动的电流水平成比例。
In frequent electronic systems, inducing variable current is a major requirement, and the strategy for doing so is as a classification of the application itself. A balanced Hall current sensor is a unit that can determine a physical phenomenon and calculate the latter, in other words, it provides a measurable demonstration of miracles within a specific scale or range. A current sensor is a device that can identify whether the current in a wire or system is high or low, and generate an indicator related to it. Then it can be used to represent the current measured in the ammeter, archived in the data acquisition system for further classification, or used for control purposes. The current sensor isInterference, as it is a combination of sensors, may affect system performance.
There are various current sensors to monitor AC or DC current, which are required for measurement in many applications in industrial, automotive, or household fields.A current sensor is a device that detects and converts current to obtain an output voltage, which is proportional to the current in the design path. When current passes through a circuit, the voltage will decrease along the path through which the current flows. In addition, a magnetic field is generated near the current carrying conductor. These phenomena are used in the design technology of current sensors.
In order to reduce power loss, the value must be taken low: the current sensed value usually depends on the threshold voltage of the circuit, and the operation of the balanced Hall current sensor is entirely based on the sensed current information.In order to improve accuracy, we must consider the low-temperature coefficient:In terms of accuracy, temperature is the main coefficient of resistance. A resistor with a temperature coefficient resistance close to zero should be used throughout the entire operation process. The power derating curve provides the allowable power at different temperatures. But the peak power capacity is a function of energy, so the energy rating curve should be considered。Introducing additional resistors in the tested circuit path may increase the source output resistance and produce adverse load effects. Due to the direction of power dissipation, power loss occurs. Therefore, current sensing resistors are rarely used for applications other than low and medium current sensing.